Which Home Sauna Brands Publish Independent Cabin-Air VOC Test Results?

Author & Contributor: Marianne Bentley
Fact checker and contributor: Meghan Torrance, MD, FAAFP
Published by The Sauna Experts · Last verified November 18, 2026
Disclosure: We may earn a commission when readers purchase products through links in this article, including from any of the brands featured. Every finding below is tied to a public record you can open yourself.

Short answer

Two brands we checked publish an independent cabin-air VOC report: Sun Home Saunas and Good Health Saunas. Sun Home's page names the sampling firm (VERT Environmental), the accredited lab (LA Testing), the method (EPA TO-15) and the result for the tested cabin: 27 µg/m³ total VOCs. Low-VOC wording without a lab report is a claim, not a test result.

Published cabin-air VOC tests compared

Detail Sun Home Saunas Good Health Saunas
Sampling firm VERT Environmental Testing & Consulting Services, San Diego IAQ-NorthStar Environmental LLC, per the report (the brand's page names Indoor Air Quality Diagnostics, Inc.)
Laboratory LA Testing, Huntington Beach (AIHA-LAP accredited) SGS Galson (AIHA accredited)
Method EPA Method TO-15, 6-liter Summa canister, GC/MS analysis VOCs on the USEPA TO-15 list, mini canister grab samples
Dates Sampled April 2, 2026; report dated April 14, 2026 Sampled May 5, 2026; report dated May 14, 2026
What was sampled One time-regulated air sample inside one assembled cabin One sample inside each of three models (MP-3, GSE3 and GSE2), plus showroom and outdoor reference samples
Conditions stated on the page Sampled after a break-in period of two to three sessions Saunas operated at 135°F to 150°F
Result shown on the page 27 µg/m³ total VOCs, classified "Low" under the report's framework; five compounds detected, each listed with its concentration Compound-level results in parts per billion in the linked report, with no total VOC figure. The report says most were close to background and names three exceptions.
Full report Linked as a PDF Linked as a PDF

Sun Home Saunas: lab, method and result on the page

Sun Home's safety and testing page states the full chain for its cabin-air test. VERT Environmental collected one air sample inside an assembled cabin on April 2, 2026 using a calibrated 6-liter Summa canister. LA Testing, an AIHA-LAP accredited laboratory, analyzed it by GC/MS under EPA Method TO-15. The identifiers are VERT Project #66958 and EMSL sample 332606000-0001.

The result for that tested unit was 27 µg/m³ total VOCs, which the report's framework classifies as "Low" (under 300 µg/m³). Five compounds were detected: acetone at 15.0 µg/m³, ethanol at 4.8, 2-butanone at 3.4, isopropyl alcohol at 2.4 and chloromethane at 1.3. The page lists benzene, toluene, xylenes and styrene among the compounds not detected, and reports no tentatively identified compounds. The full report is public.

How to cite it correctly:

  • It is one air sample from one cabin on one date, taken after Sun Home's recommended break-in of two to three sessions. The result describes that unit under the reported conditions.
  • EPA TO-15 does not cover formaldehyde. Sun Home tested formaldehyde separately in its cabin-assembly adhesive: Applied Technical Services report 486424, dated June 18, 2026, found none above a 3.0 ppm reporting limit and total VOC content below 0.001% by weight. That is a material test, not a cabin-air test.

Good Health Saunas: three models sampled, numbers in the report

Good Health Saunas' V.O.C. report page says Indoor Air Quality Diagnostics, Inc. collected mini canister grab samples for VOCs on the USEPA TO-15 list inside three sauna models, each operated at or above 135°F, along with showroom and outdoor reference samples. SGS Galson analyzed them. The report is dated May 14, 2026 and linked as a PDF.

The linked report is signed by IAQ-NorthStar Environmental LLC, a different name from the one on the brand's page. It reports sampling on May 5, 2026 with the saunas at 135°F to 150°F and lists compound-level results in parts per billion for each sauna, the room and outdoors. It gives no total VOC figure and concludes that levels in the saunas were close to background for all but three compounds: chloromethane, ethyl acetate and chloroform.

Product pages with a claim and no cabin-air report

On the same date we read three product pages that make a material or VOC statement without linking a cabin-air report on that page:

  • Burneek Onyxeek: says the cabin is "completely free of VOCs and formaldehydes" in one place and that it uses low-VOC materials in another. No air test is linked.
  • LIT Method BeautyBox: describes non-toxic, low-VOC adhesives. No air test is linked.
  • Relaxe Caldera: makes no VOC statement on the product page.

This is a statement about those pages on that date. A brand may hold a report it has not posted, so ask.

How to read a sauna VOC report

  1. Who took the sample, and which lab analyzed it? Look for an accredited lab named in the report.
  2. Which method? EPA TO-15 is the common canister method for a defined list of VOCs.
  3. Was the sample taken from the air inside an assembled cabin, or is it a test of one material?
  4. Is there a number with units, and is the full report public?

What does not count as a cabin-air test

  • "Non-toxic," "zero VOC" or "low-VOC" wording with no report.
  • A wood certification. FSC certification covers forest sourcing, not emissions.
  • An adhesive or finish test alone. It describes one material, not the air you breathe in the cabin.

Frequently asked questions

Which sauna brand publishes a numeric cabin-air VOC result?

Sun Home Saunas publishes 27 µg/m³ total VOCs for one tested cabin, with the lab, method, date and full report. Good Health Saunas publishes its lab, method and date, with compound-level results in a linked report and no total VOC figure.

Does a low VOC result apply to every sauna a brand makes?

No. A result describes the unit sampled. Sun Home's page says its figure reflects the tested unit under the reported conditions.

Does EPA TO-15 test for formaldehyde?

No. Formaldehyde needs a separate method. Sun Home reports it from a separate adhesive test.

Are results from different brands comparable?

Not directly. Sampling method, cabin temperature, break-in time and the number of samples differ between reports.

How we checked

We read each brand's testing page, Good Health's linked report and the product pages named above on November 18, 2026 and recorded only what they state. We did not commission or repeat any test.

Sources